Having right-sized range hoods means a kitchen can efficiently clear the smoke and grease while keeping fan noise to a minimum. At Bonnycastle, we can introduce you to a wide variety of choices so you can find just the right thing for your Louisville, KY home.

Factors in Choosing Among Range Hoods for Your Louisville, KY

Width

Start with measuring the width of the unit above your cooktop, because the bottom edge of your range hood must cover the full cooking surface. A unit that exactly matches the cooktop width should be your bare minimum, and even better results come when the unit extends at least three inches past each side. If you have an island setup, you need more width because the air moves freely on all sides of the cooktop.

Vertical Gap

Next, measure the vertical gap so you can place the bottom of the unit between 24 and 30 inches above your electric or induction surface. Gas cooktops need a bit more clearance, usually 28 to 36 inches, so there’s no chance heat could damage the unit. If you put the hood too high, though, the capture rate drops, so always check the maker’s sheet for the exact range.

Airflow Capacity

Manufacturers rate the airflow in cubic feet per minute. For gas cooktops, you’ll want to add the total BTU output of every burner you have and then divide that by 100. So, or example, a 60,000 BTU surface would need at least 600 CFM of power in the hood. Electric ovens need about 100 CFM for each linear foot of width. Always choose a rating that’s a little above the minimum, because that’ll allow the fan to run at a lower speed most of the time.

Noise

Noise itself is measured in sones, and one sone matches the hum of a quiet refrigerator. Normal talk is about four sones. Look for an HVI-rated unit that’s under three sones when moving 200 CFM or more. Multi-speed controls are always good so you have the option to run a high setting only when searing or frying and then drop to a lower, quiet setting once the food is done.

Capture Efficiency

A deep canopy that hangs close to the surface traps more of the rising plume than a shallow flat design, and the ideal is a unit at 80% or higher capture. Not all hoods have a published number, so look for a wide, deep shape, which performs better than a narrow shallow one at the same CFM.

When you put all these numbers together, you avoid two common mistakes: choosing an undersized or oversized unit. An undersized unit runs at full speed all the time and still leaves haze. An oversized unit on a short restricted duct creates turbulence and noise.

Visit us at Bonnycastle Appliance & TV today to check out models in person and talk through the measurements for your space. Our team has served local kitchens for more than a century.